Questions & Responses Released to All Sellers
![]() |
Buy #: 1109289_01
|
Question Deadline:
08/10/2022 14:30 ET
|
Question Count: 4
|
![]() |
Buy #: 1109289_01
|
Question Deadline:
08/10/2022 14:30 ET
|
Question Count: 4
|
Question Submitted:
1. Total CFM required.
2. Site address
3. What is the air used for?
Response Received:
1. 65-75 cfm
2. 585 SGT Joe Nurre Wheeling, WV 26003
3. Maintenance shop operations i.e. air tools, lift devices, pressure testing
5000 gallon fuel tankers
|
Question Submitted:
Manufacture is providing two different size for the receiver tank, 1. 120 gallon 2. 240 gallon Can you please suggest which size looking for?
Response Received:
We currently have a 160 gallon tank. I'm not as familiar with the screw type compressors but from what I understand they do not require as much volume to store air in reserve. Can the vendor recommend a size based off what we currently have? If not I would think the 120 gallon tank would suffice, based off above.
|
Question Submitted:
Good Morning, I have a question, What voltage do you need for the RS15ie air compressor? 230V or 460V Also would you like this a base model or a tank mounted unit? Thanks You.
Response Received:
My shop supervisor told me 480V. The Ingersoll-Rand Model number is RS15ie with max pressure of 200 psi if that helps you narrow down the exact equipment. The picture on the company website shows a tank mounted unit.
|
Question Submitted:
Will filters be needed for the dryer? I was told that the dry can take two filters.
Response Received:
I do not think we will need a refrigerated air dryer filter system. We have a remote tank and dryer system already but it is older and we have issues finding parts for service and repair when needed. It may be beneficial to look into getting a complete system with tank and air dryer if feasible.
|
![]() |
Buy #: 1109289
|
Question Deadline:
08/08/2022 15:00 ET
|
Question Count: 1
|
![]() |
Buy #: 1109289
|
Question Deadline:
08/08/2022 15:00 ET
|
Question Count: 1
|
Question Submitted:
What voltage is needed? Is the compressor going to be tank mounted? Will dry air be needed?
Response Received:
The voltage our current compressor was using was 480V. We have an external air tank that it would feed into with a concrete pad next to the tank. Yes, we will need an air dryer since our current does not work properly because of its age and the inability to get parts.
|
Unison Marketplace Process Help
Help and Training page which includes training videos, interactive help, and more. A link can also be found on the top right of every page, after log in.
For additional information, please contact:
Marketplace Support
Tel: (877) 933-3243
Contact Marketplace Support
For additional information, please contact:
Marketplace Support
Tel: (877) 933-3243
Contact Marketplace Support