Question & Responses for Buy # 1065442_05

Questions & Responses Released to All Sellers
Buy #: 1065442_05
Question Deadline:  05/25/2021 13:00 ET
Question Count: 0
Buy #: 1065442_05
Question Deadline:  05/25/2021 13:00 ET
Question Count: 0
The Buyer has not released any questions/responses to all Sellers for this Buy.
Buy #: 1065442_04
Question Deadline:  05/24/2021 16:00 ET
Question Count: 2
Buy #: 1065442_04
Question Deadline:  05/24/2021 16:00 ET
Question Count: 2
Question Submitted:
#1: Due to the design process involved for the new Wash Rack, we believe 90 days for project completion will not suffice. Please consider minimum 180 days. #2: Please provide additional information (ie: size/dimensions) of the ceiling and exterior light fixtures to be installed #3 - Requirements indicate to extend existing concrete floor slab. Taking into consideration the existing concrete wall and column footings need to be demolished and rebuilt, which will impact the existing concrete floor slab, we recommend it be demolished in its entirety. Please consider. #4 - Requirements indicate to regrade access ramp. We respectfully suggest this also be demolished completely rather than regraded, and a new access ramp be constructed in its place.
Response Received:
#1: Due to the design process involved for the new Wash Rack, we believe 90 days for project completion will not suffice. Please consider minimum 180 days. Response: Projected POP could be extended as needed. #2: Please provide additional information (ie: size/dimensions) of the ceiling and exterior light fixtures to be installed Response: Please refer to SOW section 6.1 #3 - Requirements indicate to extend existing concrete floor slab. Taking into consideration the existing concrete wall and column footings need to be demolished and rebuilt, which will affect the existing concrete floor slab, we recommend it be demolished in its entirety. Please consider. Response: In order to minimize damage to existing floor slab, existing wall footing and columns pedestal could be demolish up to new floor slab bottom elevation. #4 - Requirements indicate to regrade access ramp. We respectfully suggest this also be demolished rather than regraded, and a new access ramp be constructed in its place. Response: Please refer to SOW section 5.6 & 5.7
Question Submitted:
1) HOW MUCH OF THE BUILDING IS BEING DEMO"D? DOES NOT SPECIFY AS FAR AS WE CAN TELL. 2) WHAT IS THE LINEAR FOOTAGE OF CURB?
Response Received:
1) HOW MUCH OF THE BUILDING IS BEING DEMO"D? DOES NOT SPECIFY AS FAR AS WE CAN TELL. Response: Refer to SOW 5.1 (concrete slab mentioned in section 5.1 refer to existing concrete access ramp) 2) WHAT IS THE LINEAR FOOTAGE OF CURB? . Response: Assume 45 LF
Buy #: 1065442_03
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
Buy #: 1065442_03
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
The Buyer has not released any questions/responses to all Sellers for this Buy.
Buy #: 1065442_02
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
Buy #: 1065442_02
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
The Buyer has not released any questions/responses to all Sellers for this Buy.
Buy #: 1065442_01
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
Buy #: 1065442_01
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
The Buyer has not released any questions/responses to all Sellers for this Buy.
Buy #: 1065442
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
Buy #: 1065442
Question Deadline:  05/24/2021 16:00 ET
Question Count: 0
The Buyer has not released any questions/responses to all Sellers for this Buy.