Question Submitted:
Hi, In other for us to provide the best quote, we would please like the following questions answered. 1. What floor will the installation take place on? 2. Does your building have a freight dock? 3. Is there proper equipment available at the ship-to address to unload the freight (pallet jack, fork-lift, etc.)? 4. Floor Protection 5. Does the building require union labor? 6. What Time of the day do you require the install to be done? 7. How many stairs will the furniture need to be carried up or down to get to the installation site? Thank you
Response Received:
1. What floor will the installation take place on?
It's a normal tile floor.
2. Does your building have a freight dock?
There is no freight dock on the building.
3. Is there proper equipment available at the ship-to address to unload the freight (pallet jack, fork-lift, etc.)?
Yes we have access to a pallet jack and forklift.
4. Floor Protection
There is just a tile floor.
5. Does the building require union labor?
The building does not require union labor.
6. What Time of the day do you require the install to be done?
Between 06:30am to 5:00pm, Monday through Thursday.
7. How many stairs will the furniture need to be carried up or down to get to the installation site?
The installation will be on the first floor. There are no stairs.
|
Question Submitted:
1. Can we deliver and install the product during business hours? 2. Is there a loading dock? 3. If there isn't a loading dock, where will we offload the truck? 4. Approximately how far is it from the truck offload site to the install location? 5. Are there any stairs that the product will need to go up or down to reach the install location? 6. Will we use a passenger or freight elevator for delivery to the install location? 7. Are we required to provide power strip surge protectors to plug into the existing outlets at the walls? 8. Are we required to provide Ethernet cables to plug in to the existing CAT5/CAT6 jacks at the walls? If so, do you require CAT5e or CAT6?
Response Received:
Thank you for your excellent questions. 1. Our business hours are from 6:30am to 5:00pm Monday Through Thursday. Yes, you can deliver during business hours. Actually, you can only deliver during business hours. 2. No loading dock. 3. The truck can be offloaded at the back door of the building. It's about 150-200 feet from the room to the back door. I have access to a fork lift and driver if needed to offload the truck. 5. There are no stairs. 6. No need to use an elevator. 7. Please provide a 200 joule or higher rated surge suppressor per unit. 8. I got with the IT folks on the ethernet cables. Please provide four 25 foot Cat 6 tails terminated with RJ-45 connectors per unit. They must be terminated to the 568B standard. Please add a four port face plate in a convenient location in the cube.
|
![]() |
Buy #: 1096796_02
|
Question Deadline:
None
|
Question Count: 3
|
![]() |
Buy #: 1096796_02
|
Question Deadline:
None
|
Question Count: 3
|
Question Submitted:
would 80'' high be acceptable, since minimum is 72''
Response Received:
80" is perfectly fine
|
Question Submitted:
Would it be possible to present a more detailed floor plan (with measurements etc..)
Response Received:
If you look at the Visio file, you'll see that the measurements are embedded in the file. You must have Visio to see them.
|
Question Submitted:
Do you guys have a CAD or a DWG file of the floor plan (for exact measurements)?
Response Received:
I'm sorry. Unfortunately we don't have those capabilities.
|
![]() |
Buy #: 1096796_01
|
Question Deadline:
None
|
Question Count: 2
|
![]() |
Buy #: 1096796_01
|
Question Deadline:
None
|
Question Count: 2
|
Question Submitted:
Can you please share room drawings or sketch?
Response Received:
I've tried that, but there doesn't seem to be anywhere to do that on this tool. The room is 30' x 50'. I plan on taking up 30' on the North side of the room and 50' on the south side, so the cubicles need to be able to fit in that space. So I calculate that they need to be just under 10' wide in order to fit. I will attempt again to attach a sketch, but I may have to close this bid out and start a new one.
|
Question Submitted:
Thank you- do you have a plan of the space or how these are to be set up? In a pod of 8, straight run of 8? Single? Also- What the cubicles surfaces are? L shaped? U shaped?
Response Received:
There will be one run of five cubicles and one run of three cubicles on each side of the room, with doorways facing inward. I am going with L shaped surfaces.
|
![]() |
Buy #: 1096796
|
Question Deadline:
None
|
Question Count: 1
|
![]() |
Buy #: 1096796
|
Question Deadline:
None
|
Question Count: 1
|
Question Submitted:
Do you need just the cubicles or the desks, pedestal files, keyboard and overhead storages included? Can you please include an example picture of what you are needing?
Response Received:
I believe that I mentioned that I need everything including desks, under desk cabinet, overhead storage etc. Please reread the RFQ. I would include a picture, but I don't see any way to do that with this system. I'll try to attach one to the initial RFQ. No guarantees that that will work.
|
Unison Marketplace Process Help
Help and Training page which includes training videos, interactive help, and more. A link can also be found on the top right of every page, after log in.
For additional information, please contact:
Marketplace Support
Tel: (877) 933-3243
Contact Marketplace Support
For additional information, please contact:
Marketplace Support
Tel: (877) 933-3243
Contact Marketplace Support