Question Submitted:
THANKS FOR THE RESPONSE TO OUR SUPPLIER QUERY. OUR SUPPLIER HAS INFORMED THAT TECHNICALLY IT IS ESSENTIAL TO CHECK THE EXISTING SYSTEM BEFORE SUBMITTING A TECHNICALLY ACCEPTABLE BID. SINCE OUR SUPPLIER IS LOCATED IN COLORADO , IT IS VERY CONVIENENT FOR THE TECHNICAL PERSON OF OUR SUPPLIER TO VISIT THE SITE AND CARRYOUT ISPCTION OFTHE EXISTING SYSTEM. PLEASE THEREFORE ALLOW TOOUR SUPPLIER TO CARRY OUT INSPECTION OF THE EXISTING SYSTEM AND ALSO EXTEND THE CLOSING DATE OF BUY TO 11/11/2022 AWAITING YOUR REPLY URGENTLY TODAY
Response Received:
No extension is being given
Question Submitted:
I am still waiting on pricings I will need a couple of more days. Suppliers are reluctant to bid.
Response Received:
No extension is being given
Question Submitted:
WE HAVE JUST RECEIVED THE FOLLOWING EMAIL FROM OUR SUPPLIER We really need to either check the electrical in person or get a close up of the tag on the Friedrich units to make sure we have the electrical we need. We should ask about permitting requirements on the base Can you get us some answers or access to the buildings? KINDLY REPLY URGENTLY TODAY.
Response Received:
The Friedrich units are being replaced by the requirments outlined in the contract. The vendor needs to come up with a system that can heat and cool the building that is shown in the other picture (approx 1000 sq. feet). Whatever system the vendor uses, the vendor must completly wire it to standard. the vendor must also remove the current system completly and haul away the old material from the site. Once the contract is award access will be awarded to the installation, that process is not long or difficult.
Buy #: 1121976_01
Question Deadline:  11/03/2022 11:00 ET
Question Count: 4
Buy #: 1121976_01
Question Deadline:  11/03/2022 11:00 ET
Question Count: 4
Question Submitted:
THE INQUIRY WAS SEWNT TO OUR SUPPLIER.SINCE THE INSTALLATION OF THE SYSTEM IS ALSO REQUIRED, OUR SUPPLIER HAS ASKED US TO REQUEST YOU TO PROVIDE THE INSTALLATION DRAWING SO THAT IS SUBMITTED ON SUPPLY & INSTALLATION AWAITING YOUR IMMEDIATE REPLY WITH INSTALLATION DRAWING.
Response Received:
These are two prefabricated metal buildings around 1500 sq feet max, with the original HVAC system. You will need to just just remove the original systems and install the new one
Question Submitted:
Where will the equipment be installed? First floor? Second floor? Are there any physical or environmental obstructions? Can you include any photos? Thank you.
Response Received:
Inside a two prefabricated buildings, both of them are just one floor and approximately 1500 sq. feet.
Question Submitted:
Can you please provide a statement of work and extend the due time? Could use another week.
Response Received:
The job is straight forward and there is no extension to the date
Question Submitted:
Hello does this have any thing to do with any existing jobs?
Response Received:
No, this is to replace the original units that are in place and install new ones
Buy #: 1121976
Question Deadline:  11/03/2022 11:00 ET
Question Count: 2
Buy #: 1121976
Question Deadline:  11/03/2022 11:00 ET
Question Count: 2
Question Submitted:
Is it possible to get a layout of the building and/or a drawing that will show where the condensers and highwall air handlers will be installed? Are there any existing old equipment to be removed? This information will help us in giving an accurate bid estimate. Thank you.
Response Received:
It's an open room, the only items that this contract will have you to remove would be the existing HVAC systems which are about 6' x 4' 3' (2 ea. building) along with all the air ducts and wiring in two prefabricated building. Then install the new ones, wire install, test, haul away all your debris in your own dumpsters, ensure everything is working to code before leaving then come back back in a few weeks to ensure the systems are stable and no iisues.
Question Submitted:
Please attach a SOW. Thank you.
Response Received:
This is a full "Turn Key" contract. The vendor will be required at a minimum to take out the old systems, remove all debris from the job site, install "to code" the new system, service the new system, validate that the new system is up and running as it should be, haul away all debris from the job site, come back at a specified date to recheck the systems to ensure that there are no issues. Again this is intended to be a "Turn Key" contract and the things that were just layed out are just a sample of what is expected to be accomplished.